Here's a selection of relevant articles about flash point from AEC companies and organizations, including Ametek, Corle Building Systems and Garland Co. Inc.The.

Report Site

Corle Building Systems, Imler, PA, Steel Buildings, Metal Buildings, Commercial, Retail, ...
...Corle Building Systems uses Sherwin-Williams Kem Aqua 70P Water Reducible Metal Primer on all mainframes. It offers excellent corrosion resistance, early water resistance, and no flash point. Key Features of Sherwin-Williams Kem Aqua 70P: - Fast air drying. - VOC is less than 2.8 lbs/gal. - Excellent adhesion to untreated clean metal, both cold and hot rolled steel. See #1.

Surface: MSDS
...use whatever means of extinction are appropriate to the type of fire. Sensitivity to mechanical impact/static discharge: Not susceptible to static discharge or static discharge. Flash point (Method): None Lower/upper flammable limits (% by volume): N/Ap Auto-ignition temperature: N/Av Hazardous combustion products: None SECTION V - REACTIVITY DATA Stability: Stable. See #2.

DEPENDABLE SKIMFLOW ES
...powder PHYSICAL STATE: Solid pH: Slightly alkaline SOLUBILITY IN WATER: < 1% at 22° C SPECIFIC GRAVITY: 2.7 VAPOR PRESSURE: Not applicable FIRE AND EXPLOSION HAZARD DATA FLASH POINT: Not available FLAMMABLE LIMITS: Not combustible HAZARDOUS COMBUSTION PRODUCTS: Although primarily a refractory material, the small amount of organic ingredients... See #3.

Sierra Sales- PE Tank Standards- CALL SIERRA 215-258-5602
...for any approvals, however Snyder tanks DO meet the same UL Class 3B standards that one of our XLPE tank competitor's tanks meet. This standard simply states that materials with a flash point higher than 200 F can be safely stored. The equivalent NFPA standard for above ground storage tanks is NFPA 30. 2. Relationship of wall thickness and tare... See #4.

Celcore Incorporated
...Stable Hazardous Polymerization Will not occur Conditions to Avoid Oxidizing Agents Appearance & Odor White Powder, Slight pH 4 - 6 Section lV Fire & Explosion Hazard Data Flash Point High dust concentration may cause explosive condition. Flammable Limits Combustible Section V Health Hazard Data There are no known health effects caused... See #5.


ESECO Speedmaster Revolving Darkroom Doors and Windows
...normally installed at a height 36" (91 cm) to 42" (107 cm) from floor eliminating potential safety hazards when working in darkroom conditions. Made of Dow Lustran ABS (Flash Point 730°F - 752°F [388°C - 400°C], conforms to UL Flame Class Rate of 94 HB), the window will never need painting and will not dent, crack or tear upon impact. See #6.

Selig Industries
...Particulate pre-filters to capture suspended solids Grease and oil filters to trap soluble greases and oils and prevent the build-up of sludge Work lights Non-hazardous, high flash point cleaning fluids Lease-to-Own plans Recovery System 30 >> Recovery System 45 >> Durable, Flo-thru Brush 34"L x 26.15"W x 10.075"D... See #7.

 

Flashing Bond® EF: Garland
3 mm thickness) Flashing Repairs 1/4 in. thickness (6.3 mm thickness) 5 - 6 ft.²/gal. (0.12 - 0.15 m²/l) 7 lin.ft./gal. covers 8 in. wide (.27 m/l covers 20 cm wide) Flash Point (ASTM D 93) 100°F (38°C) min Density @ 77°F (25°C) (ASTM D 1475) 8.3 lb/gal (0.99 g/cm³) Non-Volatile (ASTM D 4479) 75% min. Packaging... See #8.

HMIS® III - Questions About HMIS® Ratings
...rating may also reflect additional hazards determined through evaluation of chemical exposure, use, and handling information. Flammability ratings are assigned according to the flash point and boiling point of the material, while Physical Hazard ratings are based on the material's physical characteristics and potential to release violent... See #9.


ZRC - ZRC Galvilite Galvanizing Repair Compound
5 mil dry film thickness 3.4 M ² /Kg @ 38 µ dry film thickness MINIMUM SHELF LIFE: Liquid — 3 Years Aerosol — 1 Year FINISH: Shiny, silvery gray FLASH POINT: 111°F (43°C) (SETA method, ASTM D3278) WEIGHT PER GALLON: 24 Lbs (ASTM D1475) MASS DENSITY: 2.797 gms/cm³ VISCOSITY: 2500 cps. Brookfield... See #10.

IPA Systems
The correct use of DURIPAL – H does not affect the appearance of the treated surface. It will not leave a glazed appearance. TECHNICAL DATA Color: Clear Odor: None Flash Point: None Toxicity: None in normal use Gases: Surfaces impregnated with DURIPAL-H remain permeable to gases and vapor. Liquids: DURIPAL-H reduces the surface... See #11.

Material Safety Data Sheet (MSDS)
2400 F - 2800 F ACIDITY/ALKANITY: Not applicable. SOLUBILITY IN WATER: % by weight Not Applicable %VOLITILE BY VOLUME: Not applicable. IV. FIRE AND EXPLOSION DATA FLASH POINT: Not applicable AUTO IGNITION TEMP: Not applicable. FLAMMABLE LIMITS IN AIR: Not applicable. FIRE & EXPLOSION HAZARDS-EXTINGUISHING MEDIA: Stainless... See #12.

Technical Talk -- Newsletter for Engineers on Electrical Cleaning Solvents: Replacing 1, 1, 1, ...
Both these solvents have been phased out of production, and are becoming hard to find. Volume 14 described the relationship between evaporation rate and flash point in alternative hydrocarbon solvent cleaners. We saw that, with hydrocarbon type cleaners, the faster they evaporate, the more combustible they are. End... See #13.

Crumpler Plastic Pipe, Inc.
Ample cuttings as described above will prevent the buildup of weed-grass fuel potential for plastics. Bituminous covered pipes however have a lower flash point of approximately 400 ˚ F and would still require some type of headwall. In summary, there are numerous risk reduction installation management practice... See #14.

 

Pye Barker Fire Safety - Frequently Asked Questions
A fuel - some sort of combustible solid, liquid or gas 2. Oxygen to react with the fuel 3. Heat - there must be enough heat to get the fuel above its flash point. There is paper on your desk right now that is surrounded by oxygen. It does not burn unless you get the paper hot enough. If you want to put out a fire, ... See #15.

Flash point (http://www.ametek.com)

...- Instruments for analysis of vapor pressure, Flash Point, Viscosity, Density, Breaking Point, Compositional...
Home Contact Us Quick Search about us Overview Our Businesses Our Brands Our Industries Gift Catalog investors Corporate Information Stock and Shareholder Information Financial News & Information... See #16.

1: http://www.corle.com [c1507504]
2: http://www.surfaceinteriors.com [c1614194]
3: http://www.floorprep.com [c1556074]
4: http://www.petanks.com [c1622073]
5: http://www.celcoreinc.com [c1554709]
6: http://www.eseco-speedmaster.com [c1603067]
7: http://www.seligindustries.com [c1613560]
8: http://www.garlandco.com [c1508511]
9: http://www.paint.org [c1510559]
10: http://www.zincrich.com [c1607994]
11: http://www.IPASystems.com [c1608181]
12: http://www.heckmannbuildingprods.com [c1514781]
13: http://www.polywater.com [c1605991]
14: http://www.cpp-pipe.com [c1602270]
15: http://www.pyebarkerfiresafety.com [c1516414]
16: http://www.ametek.com [p898017]

More than 16 companies and organizations in Architecture, Engineering and Construction offer information about flash point on their websites. The most relevant pages are shown above. To find the remaining references please use the search tool in the left column.


Add your web page here?
Please send your link and description (at least 20 words) to addpage@cadinfo.net. Placement is free. We reserve the right to refuse or modify your contribution.

Have your web page removed?
Please send a note to removepage@cadinfo.net. After verifying your request we'll remove all references to and images of your site.

 





Copyright © 2004-2009 Actiosoft / Digital Business Media: compilation of news, articles, white papers and web references concerning flash point.