First Time Buyer's Guide
...changes in the local code can occur without knowledge. It is important that you speak with a plans examiner and find out the following information: Building Code and Year Wind Load Live Load (is tributary reduction allowed?) Snow Load Seismic Zone or Coefficients Importance Factors for Wind and Snow ( See Nomenclature for help with terms ) It... See #2.
Hi Pro Intl.s Ul Listed & FM Approved Smoke Vents
...arranged as to open both lids without disturbing the fusible link assembly. All parts are corrosion resistant. The Acrylic and Metal lids shall be manufactured to support a 40 psf live load. Replacement Acrylic Standard Skylights Curb Mounted Insulating Curb Thermal Break Thermal Insulated Curb Thermal Curb Mount Size Gallery Custom Skylights... See #3.
Corrugated Metals: 2.67 x 7/8 corrugated roofing and siding
...U/D Special Inquiry 47" MF/SE 45 1 / 3 " 42 2 / 3 " 2 Down Standard 48 1 / 3 " MF/SE 45 1 / 3 " 45 1 / 3 " 1 U/D Stock 51 1 / 2 " SE 48" 48" 1 U/D Stock PANEL CORRUGATED 2 1/2 X 7/8 LIVE LOAD 20 PSF 30 PSF 40 PSF 50 PSF SPAN ROOF WALL ROOF WALL ROOF WALL ROOF WALL 18 263 lbs/sq 1 9'-1" 10'-9" 8'-1" 9'-4" 7'-1" 8'-2" 6'-5" 7'-4" 2 9-9 11-7 8-1... See #4.
Knudson Manufacturing, Inc.
...here to view product specifications KR-18B With its high strength design and exceptional engineering, the KR-18B produces a UL 90 panel with strength as its #1 priority. Exceptional live load capabilities are standard with this panel system. Profiles: 2 ½” Trapezoidal Material Gauge: Steel:.021” –.051” Aluminum:. See #5.
Heat&Smoke
...automatically in less than 5 minutes at temperatures not exceeding 500° F. Units have acrylic glazing and are available in single or double glazed. They withstand a uniform live load of 40psf and can be retrofitted onto existing built-up and metal building roofs. 417 & 418 FM Approved Automatic Melt-Out (Drop-Out) Heat & Smoke... See #6.
Line Shaft Hoists for Theatres and TV Studios - Peter Albrecht Company
...including variable speed hoists. Hoists are shipped in approximately 20'-0" long segments. 653Z LINE SHAFT HOIST SPECIFICATIONS HOIST MODEL # TOTAL LOAD CAP LBS. (MAX) LIVE LOAD CAP LBS. SPEED F.P.M. # OF DRUMS CABLE DIA. INCHES TRAVEL FT. BATTEN LENGTH FT. (MAX) DRUM DIA. INCHES MOTOR HP 1 2 4 3 550 430 23 4 3/16" 30'-0" 40'-0" 7. See #7.
products
SolarWhite™ panels weigh approximately 20lbs. per square foot when using 8" square hollow glass block with standard aluminum metal framework and will maintain a minimum live load capacity of 60lbs. per sq.ft on a 5'-0" span. Prefabricated, load bearing, composite, monolithic glass block SolarWhite™ panels are thermally... See #8.
Staging Concepts - Platforms
...surface: Polypropylene (black vinyl), fiberglass, carpet, Extendere (non-skid fiberglass), Plyron, natural wood, painted wood, or tongue and groove wood. 3. Deck will support live load of 125 psf (610kg/sq meter). 7008 NORTHLAND DRIVE SUITE 150 • BROOKLYN PARK, MN 55428 TOLL FREE 800.337.5339 • P 763.533.2094 • F 763. See #9.
[ Bin Features ]
One of the Strongest Roof Systems on the Market Certified to withstand a 20 lbs. per square foot live load. Stands up to heavy wind and snow loads One temperature-sensing cable may be attached to each rafter with no additional reinforcement required. Heavy, full circle tension ring, at eave, stablizes roof under all loading conditions. See #10.
Roof Hatches
...Concealed torsion bar in cover assists operation Automatic hold-open arm Opens to full 90° Sizes 3' x 2-1/2' to 4' x 4' Steel and galvanized prime painted Supports 70 psf live load Cover has 1" of efficient insulation to provide U-value of.17 (Optional 2" insulation offers a "U" of.09) Zinc or cadmium plated hardware. See #11.
Bridges - Sentinel Structures, Inc.
Both stringers and deck panels should be pressure preservatively treated per AITC 109 and AWPA C28. The American Institute of Timber Construction (AITC) recommends a live load deflection criteria of L/300 for timber bridges. AASHTO recommends L/500; other criteria are stated to be acceptable. Considering traffic volume, speed... See #12.
Filler King Company
Span Charts Douglas Fir/Larch Roof Beams - Construction Load Roof Beams - Construction Load 2 Roof Beams - Snow Load Roof Beams - Snow Load 2 Floor Beams - Floor Live Load Floor Beams - Floor Live Load 2 Alaskan Yellow Cedar Roof Beams - Construction Load Roof Beams - Snow Load Floor Beams - Floor Live Load Conversion Charts... See #13.
Superior Wood Systems | 800-375-9992 | SWI-24, SWI-34 and SWI-44 Floor
Joist Tables
SWI - T Series Joists Maximum Simple Floor Spans 40 psf Live Load / 10 psf Dead Load SWI-24 SWI-34 SWI-44 O.C. Spacing 9-1/2" 11-1/4" 11-7/8" 14" 9-1/2" 11-1/4" 11-7/8" 14" 16" 18" 20" LL Defl. L/360 12" 16'-10" 19'-8" 20'-6" 23'-2" 19'-6"... See #14.
Powell Valves - Cryogenic Bronze and Stainless Steel Globe and Angle Valves
Cryogenic Bronze Globe and Angle Valves Class 200 & 300, Threaded, Silver Brazed Ends Features: Rust proof handling Live load packing - Disc springs provide constant force on packing New packing design - three piece PTFE packing offers improved sealing and the 25% glass filled PTFE bottom provides additional stem... See #15.
www.makosteel.com
BOAT / RV GARAGES! 20' X 40' X 12' = $7, 700 20# LIVE LOAD / 80 MPH WIND LOAD 26 GAUGE COLOR MULTI-RIB EXTERIOR (1) 3070 WALK DOOR (1) 16'x10' FRAMED OPENING 2:12 ROOF PITCH COMPLETE STEEL & ENGINEERING DESIGN GALVANIZED STEEL FRAMING F.O.B.ADELANTO, CA 20' X 50' X 16' = $8, 500 20# LIVE LOAD / 80 MPH WIND LOAD 26... See #16.
|