Expansion Control Joints
...Control Joint Wing size 1-3/4" x 1-3/4". Used to provide mechanism for movement to accommodate expansion and contraction caused by initial stucco shrinkage and minor thermal movement. return to top return to home Niles Double "V" Inside Corner Expansion Control Joint Similar to the standard Double "V", roll... See #2.
CTS Cement — Komponent — FAQs — For Non-Shrink and Low Shrinkage Concrete
...Questions Q: What is the recommended joint spacing? A: What is acceptable and economical while maintaining the 3:1 length-to-width ratio? It is recommended that areas exposed to thermal movement be limited to 100 x 100 feet. We have in the past placed in excess of 30, 000 square feet without any jointing. Q: What are the steel requirements? A:... See #3.
Quality Flat Roof, Green Roof and Single Ply Systems
...using traditional oxidised bitumen is that the bonding and coating bitumen are both fully elastomeric, meaning they can stretch and accommodate the continual structural and thermal movement that occurs within a building and fully recover. Non- modified materials would have a much reduced life expectancy and would eventually fail through fatigue. See #4.
R-Mer ® Wall from Garland
032-gauge aluminum version available in six standard colors Standard panel widths are 13 inches and 21 inches Standard panel heights up to 25 feet Concealed clips to accommodate thermal movement Simple one-step installation Ideal for soffits or for parapet walls and/or mansards over a solid substrate R-Mer Through-Fastened Wall System Features... See #5.
Standing Seam Roof
...a minimum 1/4:12 pitch for the new metal roof. Parkside School, Monroe, Wisconsin The panel fastening system is uniquely designed to handle the potentially damaging effects of thermal movement. Precisely-formed, factory -made metal panels are locked in place by clips inside a raised seam standing two to three inches above the roof surface.... See #6.
Xypex Corporation
...All reinforcement shall be rib deformed bar in accordance with applicable standards. Exposed concrete decks (joint free) shall contain sufficient reinforcement to minimize thermal movement and control cracking. B. Setting Time and Strength: Some retardation of set may occur when using Xypex Admix. The amount of retardation will depend upon... See #7.
PRESS INFORMATION
...can be achieved without additional flashings and as the weight of the hatches is transferred through the soaker to the building structure, it does not interfere with the thermal movement of the roof. The full range of benefits of Quantum access hatches are listed in the brochure. Made from 2mm aluminium, the access hatches are lightweight, ... See #8.
Standing Seam Spotlight V2 I2: Structural or Architectural - Standing Seam Roofing Systems...
...Can be installed on slopes near dead level Can span open purlins 1.5- to 3-inch seams Should be hydrostatic (water tight) Wind resistant Longer panel lengths Withstands thermal movement Architectural Require steeper slopes (3:12) Require solid substrate Shorter seams (1/2- to 1-1/2-inch) offer desirable asethetic Additional underlayment... See #9.
Translucent Polycarbonate Multiwall Panel System
...HIGHLY FLEXIBLE – cold forms to a 11' radius, heat formed even tighter • Wide Range of Colors • No Adhesives Required • Clean Aesthetics Created by Snap Covers • Thermal Movement is Captured Internally within the System • Unique Panel Construction • Superior Light Diffusing Properties • High U.V. Resistance on Both Sides... See #10.
Solar Control Devices Brochure
...Provide sun control devices capable of withstanding the effects of loads and stresses from dead loads, live loads, snow loads, snow drift loads, wind loads, and normal thermal movement without evidencing permanent deformation of assembly or components including blades, frames, and supports; noise or metal fatigue caused by blade rattle... See #11.
SECTION 05720 ALUMINUM HANDRAILS AND RAILINGS: SAMPLE SPECIFICATION
C. Control of Corrosion: Prevent galvanic action and other forms of corrosion by insulating metals and other materials from direct contact with incompatible materials. D. Thermal Movements: Allow for thermal movement resulting from the following maximum change (range) in ambient temperature in the design, fabrication, and installation... See #12.
Alifabs - Building Products
Building Products / G55 Gutter System / Performance G55 Gutter System - Performance Thermal movement Coefficient of thermal movement is 24.0 x 10-6 per deg C over the range 20°C to 100°C. The design of joints allows for movement, and expansion gaps 2 to 3mm wide should be left between 4m lengths of gutter and downpipe. See #13.
Rubber Roofing Systems for EPDM, Hypalon, Bitumen & Metal Roofs from Truco, Inc.
The system cures to form a seamless rubber membrane which not only waterproofs and protects the roof, but also offers 82% reflectivity to reduce thermal movement and cool ambient air temperatures at AC intakes. With exceptional bond strength, low permeance, and Class "A" approval for fire & hail resistance, a... See #14.
Arch
Fashion designed systems offer finished products (no exposed fasteners), uniform and virtually flat pans, concealed clips that allow for thermal movement, and simple installation without the need for special tools. Fashion's product offering includes: (7) Standing seam selections including a UL 90 tested... See #15.
Adsco Manufacturing - expansion joints
...pressure gas duct systems at temperatures up to 1100° F. High Pressure Compensators Adsco High Pressure Compensators provide an economical and efficient method of absorbing thermal movement in small steam and hot water heating systems. Home | Engineering | Contact Us. See #16.
|