U-value

Please find below a selection of relevant articles from AEC companies and organizations for u-value.

Home Guard Windows
...Value" which gives an indication of that windows tendency to transfer heat either in or out, or by an "R Value" which describes the windows resistance to transferring heat in or out. U-Values are a measure of heat conductance R-Values are a measure of heat flow resistance If a window's R-value is high, it will lose less heat than one with a lower R-value. See #1.



Multiwall Panel System Technical Data
...INFORMATION 16 mm Panels Clear Opal Ice Mist Bronze Green Blue Light Transmission (%) 63 21 48 31 59 58 Shading Coefficient.77.55.68.65.74.73 Solar Transmission (%).67.28.59.57.65.64 U-Value, Btu/ft 2 h°F (according to EN674) 0.41 0.41 0.41 0.41 0.41 0.41 R-Value, (1/u) ft 2 h°F/Btu 2.44 2.44 2.44 2.44 2.44 2.44 SUGGESTED ARCHITECTURAL SYSTEM TESTING 1. See #2.

Kingspan Insulation
...new build, refurb, refurbishment, non-deleterious, ozone, depletion, potential, sitework, site, building, construction, fixing, health and safety, resistance, conductivity, range, u-value, r-value, reliable, foam, eco-friendly, roofs, floors, roof, floor, wall, walls, board, partial fill, nilvent, insulated, Wm2K, W.m2.K, W.m2/K, W/m2.K, W/m2K, W/mK, W/m. See #3.

Security Glazing - Technical Information for Fauser Security Windows and Doors
...and certified for a maximum size of 5' x 7' per panel. Larger sizes are possible but loose their DIN certification. Maximum glazing panel size which can be manufactured 12' x 8.5'. U-Value for double pane security glazing is 0, 29. Important: Depending on the level of security, the increased weight of the glazing is an important factor in designing... See #4.



Kalwall - Translucent Daylighting Wall Panel Systems
...to channel any moisture to building exterior. LEED ® contribution. Kalwall 100 ™ are 4" (100mm) thick panels for applications requiring even more structural integrity. U-values from 0.08 to 0.15 BTU/(hr/ft ² /ºF) or 0.45 to 0.85 W/m ² K (R-13 to R-6.16). Super-insulating, light-transmitting Kalwall+ Nanogel ®... See #5.

Kingspan Insulated Panels UK > Products > Insulated Roof Systems > KS1000 Polycarb...
...or above, where the occupants or processes do not add significant quantities of water to the air. This rooflight is available to suit the KS1000 RW insulated roof panel with a u-value of 2.0 W/m²K and is available in lengths of up to 6.44m. Polycarbonate is a lightweight, high performance and durable plastic. It's versatility makes it... See #6.

The all-rounder at a moderate price
...are highly heat-insulating, offer superior resistance to alkalis and have generous safety reserves. The sheets are characterized by the following typical values: UV absorption U-value = 2, 4 W/m²K Remarks: The NO DROP coating applied to one side causes rainwater or condensation to form a film and flow off evenly. If the NO DROP surface... See #7.

Bison Precast Concrete: Products: Insulated Hollow Core Floors
Insulated Hollow Core floors are for use on ground floors, providing all the benefits of Hollow Core with added support. Bison can provide an insulated slab to give a u-value of 0.22W/m 2 for the floor and greater if required. Further Information Please click the link(s) below for product information: Commercial/Industrial Products... See #8.

325SS
TECHNICAL DATA FRAME DEPTH: 3¼” RECESSED SASH: 2½” WALL THICKNESS:.125" RATING: HC 9O AW 90 U-VALUE:.64 AIR INFILTRATION: <0.01 cfm/ft2 (50mph) CRF: 58 THERMAL BREAK: Poured-in-place urethane and debridged. FRAME CONSTRUCTION: Machined and fitted butt joints, mechanically fastened, sealed corner construction. See #9.

Win-Vent Test Results
01 12.11 90.23 300 2 1/4" Casement 90 0.01 12.11 135.34 300 2 1/4" Project Out 90 0.01 12.11 135.34 300 2 1/4" Project In 70 0.01 12.11 105.26 CRF = 54 U-Value =.56 BTU/hr. ftsq F ** 350 2 1/2" Fixed 60 0.01 12.11 90.23 ** 350 2 1/2" Casement 70 0.01 12.11 105.26 ** 350 2 1/2" Project Out 80 0.01 12. See #10.

Industrial Roofing Products - Insulation
...ozone friendly, extruded polystyrene, rigid board insulation, insulation, lightweight, structural strength, rockwool, firewalls, quilt, insulation quilt, thermal insulation, u-value, uvalue, u value, acoustic, profiles, perforated, british standards, twinskin, singleskin, industrial roofing, industrial buildings. See #11.

Window films from durable - Energy loss
window film, film, sun control, glare, heat, glass, glazing, safety film, sun, hot, solar control, tin foil, cling film, reflective, tinting, bright, shading, blinds, air conditioning, burglary, security film, u-value, protection, insulation, windows, sun protection, heat control, conservatories. See #12.

Roof Hatches 3
...spring assists operation Minimum obstruction of opening Two-point latch for tight, secure closure Covers open to full 90° Automatic hold-open arms Efficient insulation provides U-value of.17 - Sizes 5' x 11' to 8' x 8' (Special sizes available) Zinc or cadmium plated hardware. See #13.

US Block Windows The Premier Source for Privacy Window Solutions
...natural, light, cut-to-size, manufacturer, bronze, vinyl, patterns, traditional, mortar, look, flowable, silicone, u-factor, u-value, solar, heat, gain, kiln-fired, insulated, glass, horizon, tempered, limited, lifetime, warranty, flush, ... See #14.

Celotex Insulation - U-value Calculator
HOME | TECHNICAL SUPPORT | FAQs New! Flat roof board EL3 available now We know insulation inside and out 200mm - the thickest insulation in town We know insulation inside and out New! Flat roof board EL3... See #15.

Glass U-Value Performance - SECP Tables - California Glass Bending Corporation
SECP Tables - Glass U-Value Performance. See #16.

1: http://www.home-guard.net [c930530]
2: http://www.co-excorp.com [c1091723]
3: http://www.insulation.kingspan.com [c918519]
4: http://www.swissshade.com [c1088321]
5: http://www.kalwall.com [c1079642]
6: http://www.kingspanpanels.com [c992430]
7: http://www.roehm.com [c727237]
8: http://www.bison.co.uk [c1150881]
9: http://www.capitol-windows.com [c1029453]
10: http://www.winventwindows.com [c1035123]
11: http://www.wedge-roofing-centres.com [c1155929]
12: http://www.durable.co.uk [c881654]
13: http://www.milcorinc.com [c1080185]
14: http://www.usblockwindows.com [c1082658]
15: http://www.celotex.co.uk [p986841]
16: http://www.calglassbending.com [p746555]

More than 16 companies and organizations in Architecture, Engineering and Construction offer information about u-value on their websites. The most relevant pages are shown above. To find the remaining references please use the search tool in the left column.

 





Copyright © 2004-2008 Actiosoft / Digital Business Media: compilation of news, articles, white papers and web references concerning u-value.