FlameStop.com -- Fire Retardant and Flame Retardants and Intumescent Paint spray on applications
...on thermocouple placed one inch from a penetrating item in lieu of direct attachment to penetrating items. Rating periods shall conform to the following: Time-rated floor or wall assemblies: 1.2.3.4 hours are applicable. Openings between floor slabs and curtain walls: 1, 2, 3 hours are applicable. Minimum 1 hour "T" rating on all... See #5
Georgia-Pacific Building Products Home Page - Building Materials, Building Products, ...
...Specifications Assemblies and Systems CAD Drawings for Gypsum Products Submittal Forms 09 00 00 - Finishes 09 21 16 - Gypsum Board Assemblies 09 21 16.23 - Gypsum Board Shaftwall Assemblies 09 21 16.33 - Gypsum Board Area Separation Wall Assemblies 09 28 00 - Backing Boards and Underlayment 09 28 16 - Glass-Mat Faced Gypsum Backing Boards... See #6
Fassaden Winodws Site Map
...Installation Accessories Contact Us Allentown, PA.pdf Fassaden Windows Catalog Request Fassaden CAD & Specs Specification 08550.doc Section 08900 - Glazed Wood Curtain Wall Assemblies Section 08980 Standard Curtail Wall Detail Binder.pdf CAD file upload/FCW-WD01 (50).dwg CAD file upload/FCW-0001 (50).dwg CAD file upload/FCW-0002 (50). See #7
Firefree 88 - Testing & assemblies for FF88, a fire resistant, intumescent coating for...
UCB-8-2 ROOM CORNER TEST C. FM 4880 ROOM CORNER TEST D. FM 4975 CEILING TEST E. ASTM E-84 STEINER TUNNEL TEST SECTION 2 FIRE RESISTANT TEST, ASTM E-119/ULC-S101 1. WALL ASSEMBLIES ONE HOUR A. SHEETROCK B. LATH & PLASTER C. WOOD 2. WALL ASSEMBLIES TWO HOURS A. SHEETROCK 3. CEILING ASSEMBLIES ONE HOUR A. SHEETROCK B. WOOD C. PLASTER D. See #8
Fire Glass: SAFTI FIRST SuperLite II-XL 120 Minute Fire Rated Glass
Intertek/Warnock Hersey permanent labels are applied to all lites. Go to >> STANDARDS UBC STD 7-1, NFPA 251, UL 263, ASTM E-119, ULC CAN-S101 for fire resistive wall assemblies. UBC STD 7-2, NFPA 252, UL10B, UL10C, ASTM E-2074, CAN4-S104, ASTM E-152 for door assemblies. UBC STD 7-4, NFPA 257, UL9, ASTM E-2010, CAN4-S106, ASTM... See #9
Western Red Cedar Lumber Association (WRCLA)
Because of the high internal friction created by the cellular pore network, wood has more sound damping capacity than most structural materials. Floor, ceiling and wall assemblies of wood can provide effective economical sound insulation and absorption when properly utilized. Western Red Cedar is particularly effective in this... See #10
SECTION 04240
3. Lintel Blocks: a. Solid reinforced blocks: Same width as walls. b. “U-shaped” lintel blocks: Same width as walls. B. Fire Resistance: Wall assemblies shall meet ASTM-E 119. C. Mortar materials: 1. Thick Bed (3/8”) a. Portland Cement: ASTM C150, Type 1 b. Sand Aggregate: ASTM C144; use sand from... See #11
EPS Molders
(NWTHC) show that homes constructed with ICFs above and below grade wall construction have reduced air infiltration compared to other wall assemblies. 1. Slab Insulation Technology Factsheet. Office of Building Technology, State & Community Programs Energy Efficiency & Renewable Energy. U.S. See #12
AEC Daily: Fire-Resistant Ceiling and Wall Assemblies Using Gypsum Board Products
Home News Education Community Events Subscribe Contact var today = new Date(); var day = today.getDate(); var month = today.getMonth(); var year = today.getFullYear(); if(month == 0) { month =... See #13
INSULATED GYPSUM WALL ASSEMBLIES
INSTALLATION INSTRUCTIONS FIRE AND DRAFT SEALER™ SEALING PENETRATING ITEMS THROUGH INSULATED GYPSUM WALL ASSEMBLIES INSULATED GYPSUM BOARD WALL ASSEMBLIES Step 1: All surfaces should be clean, dry, and free... See #14
Performance of Finger-joined Lumber
PERFORMANCE OF FINGER-JOINED LUMBER IN FIRE-RESISTANCE-RATED WALL ASSEMBLIES. See #15
|