Northwest Rubber SportFLOOR ASTM Specs and Information
.6 ASTM D 570, Moisture Absorption..7 ASTM D624, Test Method for Rubber Properties..8 ASTM D2240, Rubber Property Durometer Hardness..9 ASTM E648-03, Critical Radiant Flux..10 ASTM F970-00, Static Load Limit 1.3 SUBMITTALS.1 Submit samples in accordance with Section [ ] - [ ]..2 Submit duplicate 300 x 300 mm sample pieces of sheet material. See #2.
SCHUNDLER COMPANY--Perlite Block and Cavity Fill--Loose Fill Insulation
...also confirm the superior qualities of perlite loose fill insulation: Test ASTM E84 Flame Spread Fuel Contribution Smoke Density Results 0 0 0 Fed. Spec HH-1-515D Critical Radiant Flux Smoldering Combustion Smoldering Combustion Results Greater than 1.07 Watts/cm20 Flaming Combustion: None Weight Loss: Nil Cost Savings: Insulation is... See #3.
Dexotex
Impact Resistance MIL-D-3134, Para. 3.15 No cracking or loosening, Indentation 0.005 in. 8. Indentation Resistance MIL-D-3134, Para. 3.16 No indentation 9. J. Critical Radiant Flux NFPA 253/FTMS 372 & ASTM E648 >1.07 Watts/CM 2 10. Flammability ASTM D635 Self Extinguishing 11. Co-efficient of Linear Expansion ASTM D696 14x10 -6 in. See #4.
Pryamid Sports Floor Systems - SportFlex
load. Indentation Resistance - ASTM F-1914 = 5.3% at 75 lb. load. basketball Recovery - DIN 18032 = 99% Fire Resistance: ASTM E 648/NFPA 253 (Critical Radiant Flux) - Class 1. ASTM E 662/NFPA 258 (Smoke Density) - 450 or less. Installation The installation of Pyramid Sport Flex Tiles should not begin until the work... See #5.
Gigahertz Optik - Light Measurement Solutions
57 sr Fig.II.6. The solid angle Ω quantifies a certain part of the visual field, seen by an observer located at P II.4.b. Radiant power or radiant flux Φ e Radiant power Φ e is defined by the total power of radiation emitted by a source (lamp, light emitting diode, etc.), transmitted through... See #6.
Tretford USA - Specifications
...Hz 125 250 500 1000 2000 4000 Absorption coefficients.03.07.10.24.46.52 PERFORMANCE SPECIFICATIONS Flame spread: ASTM E84 - Class A Smoke density: ASTM E84 - Class A Critical radiant flux: ASTM E648 - 0.71 Home | Color & Design | Specifications Installation & Maintenance | The Company | Contact Us. See #7.
Premier Tuff Deluxe
...EXPOSURE ASTM D 1149-86 No adversities AGING RESISTANCE ASTM D-750 No Change STATIC LOAD LIMIT ASTM F-970 0.004 in. ELECTROSTATIC PROPENSITY AATCC 134-1996 Neg. 0.6 KV CRITICAL RADIANT FLUX ASTM E-648 0.52 watts/sq. cm Premier Specialty Flooring | (800)-805-4654 Copyright All Rights Reserved. See #8.
Blue Ridge Carpet
66 m) Primary Backing 100% Synthetic Secondary Backing EnviroFlex® Performance Engineered Backing w/40% Recycled Content Flammability Average Critical Radiant Flux: Greater than.45 - Class 1 CRI Indoor Air Quality Carpet Testing Program Passes - Certification No. 2878. See #9.
|